.:Saving the planet, again:.
|
|
|
|
/*
|
|
* This is purely educational;
|
|
* Any knowledge gained from this document is self imposed and thus
|
|
* the author cannot be held responsible. Any activities resulting from
|
|
* knowledge gained in this document is not accountable by the author.
|
|
* If you do not accept this, please refrain from reading further.
|
|
*
|
|
*/
|
|
#include <disclaimer.h>
|
|
|
|
A more environmentally friendly way of traveling by car. As some
|
|
of you might recall in almost all the hacking movies, books, TV shows, etc.
|
|
there has been a case of someone fiddling with traffic lights. Well we all
|
|
just giggled at the unrealistic aspect of it and didn't think twice. Well in
|
|
my quest for a more appealing planet for our children I felt compelled to
|
|
think of a way in order to reduce the amount of pollution emitted by
|
|
vehicles of today.
|
|
Standing at a intersection, nobody else around, you're still stuck behind the
|
|
red light, and this invisible barrier of governmental guilt has enough power
|
|
to let you wait there and pollute the air more and more, just for a measly
|
|
green light. Wouldn't it be leet having a laptop in the car where you could
|
|
just select the intersection off a list, change the timing or current stream
|
|
running, and ride off with fewer time wasted and fewer pollutants exhausted
|
|
and a clear conscience.
|
|
|
|
Now, enough crap about the reasons, now for the technical shit.
|
|
|
|
Today's traffic controlling system is a well oiled redundant network that
|
|
utilizes the same protocols that we are all aware of. Yes it is hackable
|
|
and it is like in the movies. :)
|
|
here we go!
|
|
|
|
a description of some of the terms used.
|
|
|
|
- controller
|
|
This is the technical term for a traffic light and will be
|
|
referred to that way.
|
|
- UTC
|
|
Urban Traffic Control, solid-state signal controllers connected
|
|
to central computer by means of PSTN. Provides communication
|
|
standard for controllers (see fig. 1)
|
|
|
|
- SCOOT
|
|
Split Cycle Offset Optimization Technique.
|
|
A standard now implemented across majority of traffic systems
|
|
across the world. It provides adaptive control of controllers,
|
|
this is done by the controlling office, it receives the traffic
|
|
flow data from closed loops around the intersection, which it
|
|
analysis and relays back current configurations in real-time
|
|
back to the controller.
|
|
|
|
- ITS Intelligent Transport Systems, This is just a buzzword to describe
|
|
the whole system covering everything, UTC, SCOOT, CCTV(video) and
|
|
the whole protocol stack interlinking all of it. (see fig. 2)
|
|
|
|
- NTCIP
|
|
This is the protocol that is in process of becoming a standard
|
|
for traffic management communications. It is based on TCP/IP and
|
|
revolves mainly on SNMP that has specific MIB's for use in
|
|
controller messaging. (protocol may vary from country to country)
|
|
Some controllers in US are NTCIP compatible, namely Thereon and model
|
|
170 of NEMA controllers. CCTV, VMS, Field Processors, Ramp metering
|
|
are all linked via NTCIP.
|
|
|
|
- ATC
|
|
Area Traffic Control, This is the Central office that control
|
|
all the aspects of traffic control management.
|
|
|
|
- FEP
|
|
Front End Processor, Virtual Processing for controllers. located
|
|
before management computer, and connected directly to controllers
|
|
via instation modem rack or telemetry hardware. One FEP
|
|
supports up to 512 PSTN lines.
|
|
|
|
- OTU
|
|
In UK this is the Outstation Transmission Unit, this provides the
|
|
means of converting serial data coming from the central computer
|
|
to parallel data for use in the controller, and provides
|
|
interchangeability of controllers.
|
|
(I'm not sure if this system is a standard across the world, for
|
|
South Africa it is done by a CCIU Controller Communication Interface
|
|
Unit}
|
|
- CMU
|
|
Cabinet Monitoring Unit, This is what detects when you fiddle inside
|
|
the box next to the road. It reports hardware/software faults and
|
|
packages the data for reporting to the FEP and ATC.
|
|
|
|
|
|
|
|
Figure 1. Different link arrangements
|
|
-------------------------------------
|
|
|
|
---0 junction 1
|
|
/
|
|
0------------0----0 junction 2
|
|
CENTRAL LOCAL \
|
|
OFFICE EXCHANGE ---0 junction 3
|
|
|
|
[UTC Radial Arrangement]
|
|
|
|
|
|
---0 junction 1
|
|
/ \
|
|
0------------0 \
|
|
C.O L.E 0-- junction 2
|
|
/
|
|
/
|
|
0 junction 3
|
|
|
|
[UK Multi-drop UTC arrangement]
|
|
|
|
|
|
|
|
Figure 2. ITS Topologies
|
|
-------------------------
|
|
|
|
________ ________ ________
|
|
|COMPUTER|---|COMPUTER|------|COMPUTER|
|
|
`--------' `--------' `--------'
|
|
(coax) |_____ | (dialup) |__ (radio)
|
|
| | |
|
|
__________ | ____|_____ _____|_____
|
|
|CONTROLLER|-| | MASTER |__ |FIELD PROC.|__
|
|
`----------' | `----------' | `-----------' |
|
|
__________ | __________ | ___________ |
|
|
| VAX/VMS |-| | VAX/VMS |__| |CCTV CAMERA|__|
|
|
`----------' | `----------' | `-----------' |
|
|
__________ | __________ | ___________ |
|
|
|COUNTSTION|-| |CONTROLLER|__| |CONTROLLER |__|
|
|
`----------' `----------' `-----------' |
|
|
___________ |
|
|
| VAX/VMS |__|
|
|
`-----------'
|
|
|
|
(Physical links (Physical links (physical links
|
|
EIA 232) FSK-modem) Fiber)
|
|
|
|
|
|
|
|
|
|
Introduction
|
|
------------
|
|
|
|
The traffic controller boxes that you see on the road have all a standard
|
|
configuration set when commissioned, but they are all linked to a central
|
|
office for remote configuration changes, fault reporting, resetting, etc.
|
|
The ATC houses a FEP which connects to each controller or the local exchange.
|
|
The FEP is the direct network connection to the controllers and queries the
|
|
controllers per second bases and receives the responses which are transported
|
|
to the central controlling computer [OS/2 or ALPHA VAX in S.A and UK] via
|
|
DECnet on coaxial or other means via the LAN. The controlling computer then
|
|
analysis the result and determines faults or other data and places it in the
|
|
central controlling database on a VAX/VMS. The database is then prioritized
|
|
and can be accessed via web interface on the local intranet to see fault
|
|
reports and timing info.
|
|
|
|
When a reconfiguration is issued, an operator can set all configurations
|
|
remotely even if a total controller reset is required. This includes stream
|
|
timings (streams are the various timing configurations), local time, light
|
|
dimming, emergency stream (for ambulances and such), the different settings
|
|
will be discussed later. When the operator requests a change in configuration,
|
|
it is sent to the FEP in a large datagram which is split up and modulated
|
|
for communication to the controller. The protocols between the OTU/CCIU and
|
|
the FEP is usually not a standard, and propriety protocols are setup by the
|
|
manufacturers of the units.
|
|
|
|
a diagram of how UTC is interlinked is shown. (fig. 3)
|
|
|
|
figure 3. Protocol and physical link diagram of UTC system
|
|
----------------------------------------------------------
|
|
ATC IN CONTROLLER BOX
|
|
____________ :
|
|
|UTC COMPUTER| RS232 SERIAL :
|
|
`------------' : SERIAL
|
|
| ___ ______ : _____ : ________
|
|
| DECnet-> _______ |___|MODEM |-/--|MODEM|-----|OTU/CCIU|
|
|
TCP/IP |---------| FEP |_|___| RACK | : `-----' `--------'
|
|
ETHERNET | `-------' |___`------' : | RS232
|
|
LAN -> | : | SERIAL
|
|
| (NTCIP encompassed) : ___|______
|
|
| protocols : |CONTROLLER|
|
|
| _______ : `----------'
|
|
|___| | :
|
|
`-------' :
|
|
misc. devices :
|
|
like VAX/VMS for :
|
|
fault monitoring
|
|
and such.
|
|
|
|
|
|
The communication between the controller and the ATC is done via a
|
|
bit stream signals where certain bits represent a preprogrammed
|
|
function in a controller.
|
|
A serial second-by-second bit stream is received by each controller
|
|
continuously and is converted to parallel for use inside the controller.
|
|
The stream consists of 16 bits, Thus 32 parallel connections can be initiated
|
|
with the controller, and certain bit streams control certain functions and
|
|
some have a return value for example to notify the controller which stream
|
|
currently is running. The communication may look similar to this.
|
|
|
|
1001011011011101 sent
|
|
1000101111010101 received
|
|
|
|
as said, the comms protocol is more than likely to be propriety and thus non
|
|
standard. eg. The control bit 10 may 'mean set max green time 30s' and in
|
|
another, 'hold vehicle stage'. but according to ATC standards globally,
|
|
there are a couple of standards like stream control, emergency control
|
|
and resets and more nifty features.
|
|
|
|
But this is not important because access to the controlling computer is in
|
|
anyway necessary for control of the controller, and thus the specific
|
|
protocol used doesn't matter.
|
|
|
|
|
|
----------------------------------------
|
|
communication technical details, yummy!
|
|
----------------------------------------
|
|
|
|
UTC messaging
|
|
-------------
|
|
|
|
Below is a typical description of the communication between the controller
|
|
and ATC. UTC is the current system that is used in majority of ATC
|
|
centers across the world. And communication is pretty much standard.
|
|
The specific messaging data bits might be different in different
|
|
countries since it is done proprietly by the controller and system
|
|
manufacturers. But they tend to stick to a standard, South Africa is based
|
|
on the UK system, And the UK system is the same as America, and so it all
|
|
will look basically the same, except for area specific functions.
|
|
|
|
UTC Control and Reply Bits (Fn = F1,F2,F3... different stages, same for Dx)
|
|
---------------------------
|
|
Control Description Reply
|
|
|
|
Dn (or Dx) Demand Individual Stage SDn/SDx
|
|
Fn Force Stage
|
|
FM Fall Back Mode FC
|
|
HI Hurry Call Inhibit
|
|
Stage Confirmation, Stage n Gn
|
|
Hurry Call Confirmation or Reqst HC
|
|
Manual Control MC
|
|
Emergency Vehicle EV
|
|
Vehicle Red Lamp Failure 1 RF1
|
|
Vehicle Red Lamp Failure 2 RF2
|
|
SFn Switch Facility SCn
|
|
SO Solar Override
|
|
SG CLF Group Timer Synchronization CG
|
|
LO Lamps On/Off LE
|
|
LL Local Link Inhibit
|
|
TS Time Switch Sync Stored Value
|
|
TO Take Over
|
|
TC Transmission Confirm
|
|
CP Close Car Park CL
|
|
Detector Fault Monitor DF
|
|
CLF Group Timer in First Group GR1
|
|
Remote Reconnect RR
|
|
Entry in Controller Fault Log CF
|
|
Handset Connected TF
|
|
Lamp Fault LFn
|
|
Car Park Occup Thresh Exceeded CA
|
|
Pedestrian Green Confirm PC
|
|
Queue Detector Presence VQ
|
|
Detector Vehicle Count VC
|
|
Car Park Information CSn
|
|
Queue at Car Park Entry Reservoir CR
|
|
SCOOT Detector Presence Vsn
|
|
Cabinet Door Open CO
|
|
PV Hold Vehicle Stage
|
|
PX Demand Pedestrian Stage
|
|
Puffin Clearance Period PR
|
|
Vehicle Green Confirm GX
|
|
Wait Indicator Confirm WI
|
|
|
|
A controller is typically setup to receive 16 to 32 bits of control bits
|
|
which can be be replied to by the controller using a reply datagram.
|
|
(note that SCOOT specific functions are done in the same way)
|
|
|
|
typical Control UTC message:
|
|
|
|
Bytes 1,2 Control Bytes (Address 2)
|
|
Byte 3 (F1,F2,F3,D2,D3,DX,SO,-) (check above table for bit descr)
|
|
Byte 4 (-,-,-,-,-,-,-,TS)
|
|
|
|
0 0 0 0 0 0 1 0 0 1 0 1 0 0 1 0 0 0 0 0 0 0 0 0
|
|
|
|
typical Reply UTC message:
|
|
|
|
Bytes 1,2 Reply Bytes (Address 2)
|
|
Byte 3 (G1,G2,G3,-,-,DF,CF,-) (check above table for bit descr)
|
|
Byte 4 (-,-,-,-,-,-,-,RT)
|
|
|
|
0 0 0 0 0 0 1 0 0 1 0 1 0 0 1 0 0 0 0 0 0 0 0 0
|
|
|
|
The communication is done asynchronously and in the controller represented
|
|
as parallel, whereas in the FEP its serial. The modulation can be done
|
|
either by FEP or instation specific controller cards.
|
|
|
|
|
|
NTCIP Messaging (UK and some US ATC's)
|
|
--------------------------------------
|
|
|
|
I am not going to discuss the specific NTCIP messaging system because it
|
|
is not set as a standard yet, and basically, because I haven't had the
|
|
pleasure of playing with it. America (except NY and other big
|
|
cities), South Africa, Namibia and I think majority of countries
|
|
across the world still use SCOOT capable UTC primarily whereas
|
|
UK is adopting it as standard.
|
|
|
|
The NTCIP stack:
|
|
|
|
Layer Class A Class B Class C
|
|
-------------------------------------------------------------
|
|
Application (7) SNMP/STMP SNMP/STMP SNMP/STMP/FTP
|
|
Presentation (6) - - -
|
|
Session (5) - - -
|
|
Transport (4) UDP - TCP/UDP
|
|
Network (3) IP Null IP
|
|
Data Link (2) HDLC HDLC HDLC
|
|
Physical (1) RS232/FSK RS232/FSK RS232/FSK
|
|
|
|
A and C are not standard but could be used. For
|
|
tcp compatibility and routing.
|
|
A and C can be implemented as well as additional TCP/IP stacks.
|
|
|
|
B is defined as standard and is used for bandwidth efficient exchange of
|
|
data but does not provide assurance of delivery, this is in turn done
|
|
by the physical layer for necessary retransmission.
|
|
|
|
B only contains three layers, application, data link, physical layer.
|
|
This is because the constant line between office and controller is fixed
|
|
and thus no routing is necessary and SNMP includes the session features.
|
|
|
|
NTCIP and SNMP and some STMP:
|
|
|
|
SNMP commands:
|
|
-get
|
|
-set
|
|
-get Next/get Bulk
|
|
-trap
|
|
|
|
The manager (ATC) may send out 'get' command to retrieve information from
|
|
the agent (CONTROLLER) and waits for a reply. But SNMP does not provide
|
|
for the agent to initiate contact, and thus the manager polls periodically
|
|
with the 'trap' command. This is done on a per second basis.
|
|
|
|
The typical SNMP frame is 37 Bytes
|
|
----------------------------------------------------------------------------
|
|
|ver|community|command|req id|error status|error index|objct id|objct value|
|
|
----------------------------------------------------------------------------
|
|
|
|
ver=
|
|
SNMP v1 -NTCIP v2 included security features which they thought
|
|
was a waste of bandwidth- ;)
|
|
|
|
Id flag=
|
|
is used for matching up the messages with replies
|
|
|
|
community name=
|
|
essentially a password
|
|
|
|
core message in Object ID and Value=
|
|
the controller control data and reply section
|
|
|
|
SNMP is a bandwidth eating protocol, so they designed the STMP
|
|
(simple transportation management protocol) which is a cut down vers of SNMP.
|
|
It uses the same commands but has the added benefit of having no header and
|
|
using dynamic objects. Dynamic objects can encompass a number of variables
|
|
like time, date, year and all in one object. The objects are defined online
|
|
and both the instation and outstation parties know what the object describes
|
|
and thus just a single value needs to be transmitted. The typical size of
|
|
an STMP message is 1 byte, with a maximum of 13 dynamic objects.
|
|
|
|
|
|
Comparison Between UTC and NTCIP Messaging
|
|
--------------------------------------------
|
|
UK UTC NTCIP Class B
|
|
Polling cycle 1s 1s
|
|
Message size Fixed Variable
|
|
Device Variables
|
|
transmitted All Only parameters to be changed
|
|
Value of device
|
|
variable Bit Integer or Bit
|
|
Protocols Proprietary Standardized
|
|
|
|
|
|
|
|
-----------------------------------------------
|
|
Hacking the Traffic lights GOdDamnit! #$@#%@#%
|
|
-----------------------------------------------
|
|
|
|
Ok I wanna save the environment now, with my new UhbEr
|
|
technique.
|
|
|
|
Basically, the idea is to get access to the VAX/VMS database or the controlling
|
|
computer itself. Now since this is on a internal LAN, and runs on DECnet
|
|
we have to find clever ideas to get in.
|
|
|
|
Some social engineering can help you a whole lot.
|
|
Phone your local municipality, or check out websites, newspapers or
|
|
anywhere, where specifically, the ATC is situated. Now you will get the contact
|
|
numbers of people who work there or such, maybe a fault reporting number.
|
|
Fire up your wardialer and start scanning the prefix. They should have
|
|
a server where they dialup to commission a new controller or when a new
|
|
software d/l is needed in the field. In South Africa this is a computer
|
|
running DOS with pc-anywhere on. But if they are clever, like all of the
|
|
centers I've seen, they would have a dial-back facility, if not, your in luck
|
|
cause then you are directly linked to the internal LAN, and should start
|
|
hacking the VAX or FEP. The FEP note, is normally a propriety system, like
|
|
in South Africa, runs on DOS with some major serial comms protocols. Better
|
|
the get access to the VAX/OS2 controlling computer for a more familiar
|
|
system, although the FEP has more control of controller system messages.
|
|
And you can access the serial connections to the modems directly.
|
|
|
|
If you are unlucky and have a clever ATC. You must devise another means of
|
|
access to the internal LAN. In my experience the LAN is always connected to
|
|
the local municipality WAN for mail purposes and for access to the local
|
|
intranet for database driven fault reporting. Now to gain access to the local
|
|
WAN is not that difficult, since they are usually very big and provide
|
|
gazillion services like websites, mail servers for municipal workers and such.
|
|
Now Hax0r a web server or something and backdoor it *VERY* *VERY* well. You
|
|
gonna need it a lot, maybe backdoor a couple. :)
|
|
|
|
Now on the local WAN, you can probably access the nameserver to the ATC LAN
|
|
or you can access it directly. I'm not providing a tutorial on hacking, just
|
|
means of access, so sniff email, network traffic blah blah... till you get
|
|
access to the VAX or controlling computer.
|
|
|
|
Now once your in, backdoor it *VERY* *VERY* *VERY* well ;)
|
|
you should use all the vax hiding tools and shit, look thru phrack for VAX/VMS
|
|
hacking. There are a couple of nice SHOW USER hiding tools and stuff
|
|
written by mentor and a few others. And once you are in, check
|
|
what is on the DECnet, and maybe see if it is linked to other ATC's.
|
|
From here you can access the controlling computers, FEP's and everything.
|
|
Try to see the serial connections directly via FEP or see the communication
|
|
from the controlling computer, so you can figure out the format of messaging
|
|
controllers. Or if you are lucky, you can access the program itself
|
|
used for messaging, if its terminal friendly.
|
|
|
|
Now find a controller that you have the location for, the addresses are
|
|
pretty easy to figure out most of the time or just browse through the
|
|
VAX database of fault reports or check the local intranet. Now construct
|
|
a suitable message and datagram from captured data, and make it do something
|
|
noticeable like: UTC message - PX DEMAND PEDESTRIAN STAGE
|
|
Hopefully, you have a laptop or something, go down to the controller
|
|
that you intend to send the message to. Now you will notice that all this is
|
|
done over tcp/ip, since you link to the LAN where you get onto the VAX/VMS
|
|
DECnet and in turn the controlling computer/FEP. So send through the command
|
|
and watch if the controller obeys you. If it does then you can start script
|
|
the whole procedure ;). make nice timings for ENVIROMENTLY friendly travels
|
|
between destination A and B. Also the commands to force a stage is nice to
|
|
have, UTC message - Fn ; now if your stuck behind a red light, and just
|
|
sitting there polluting the air, just force to next stage in stream, and
|
|
off you go without the guilt of crossing a red light ;)
|
|
|
|
Also if you are browsing the LAN, look out for nifty info like, the source
|
|
to the firmware of controllers since the firmware gets updated quite often.
|
|
It might lay around on the dialup server or some internal ftp server.
|
|
The exact frequency and bit sequence used to initiate the emergency cycle
|
|
in the controllers, for ambulances and emergency vehicles is also nice.
|
|
There is also the software that is used to commission the controllers
|
|
and the hand unit for field monitoring.
|
|
|
|
Of course hacking the traffic system can be abjo0zed and have disastrous
|
|
effects, but i feel, if you have the skill to access a system like that,
|
|
then you have the sense not to fsck it up.
|
|
|
|
|
|
|=[ EOF ]=---------------------------------------------------------------=|
|
|
|