/* A little input demo for mode 2 Mode 2 uses two different timers to convert samples. The primary timer determines the time between scans, and the secondary timer determines the time between samples in a scan. The time between scans is in trigval; the time between samples is selected by trigval1. Conversion from seconds or Hz is done using the standard timer routines. */ #include #include #include #include #include #include #include #include #define N_SCANS 10 #define N_CHANS 16 int subdevice = 0; int chan=0; int range = 0; int aref = AREF_GROUND; double freq = 1000; #define N_SAMPLES 1000 double data[N_SAMPLES]; int main(int argc, char *argv[]) { char *fn = NULL; int i; comedi_t *dev; fn = "/dev/comedi0"; dev = comedi_open(fn); #if 0 for(i=0;i<10;i++){ range=comedi_find_range(dev,subdevice,chan,0,-i,i); printf("%d\n",range); } #endif comedi_timed_1chan(dev,subdevice,chan,range,aref,freq,N_SAMPLES,data); for(i=0;i