/* * yosys -- Yosys Open SYnthesis Suite * * Copyright (C) 2012 Clifford Wolf * * Permission to use, copy, modify, and/or distribute this software for any * purpose with or without fee is hereby granted, provided that the above * copyright notice and this permission notice appear in all copies. * * THE SOFTWARE IS PROVIDED "AS IS" AND THE AUTHOR DISCLAIMS ALL WARRANTIES * WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF * MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR * ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL DAMAGES OR ANY DAMAGES * WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR PROFITS, WHETHER IN AN * ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS ACTION, ARISING OUT OF * OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS SOFTWARE. * */ #include "kernel/yosys.h" #include "kernel/sigtools.h" #include "kernel/modtools.h" USING_YOSYS_NAMESPACE PRIVATE_NAMESPACE_BEGIN //get the list of cells hooked up to at least one bit of a given net pool get_other_cells(const RTLIL::SigSpec& port, ModIndex& index, Cell* src) { pool rval; for(auto b : port) { pool ports = index.query_ports(b); for(auto x : ports) { if(x.cell == src) continue; rval.insert(x.cell); } } return rval; } //return true if there is a full-width bus connection from cell a port ap to cell b port bp //if other_conns_allowed is false, then we require a strict point to point connection (no other links) bool is_full_bus( const RTLIL::SigSpec& sig, ModIndex& index, Cell* a, RTLIL::IdString ap, Cell* b, RTLIL::IdString bp, bool other_conns_allowed = false) { for(auto s : sig) { pool ports = index.query_ports(s); bool found_a = false; bool found_b = false; for(auto x : ports) { if( (x.cell == a) && (x.port == ap) ) found_a = true; else if( (x.cell == b) && (x.port == bp) ) found_b = true; else if(!other_conns_allowed) return false; } if( (!found_a) || (!found_b) ) return false; } return true; } //return true if the signal connects to one port only (nothing on the other end) bool is_unconnected(const RTLIL::SigSpec& port, ModIndex& index) { for(auto b : port) { pool ports = index.query_ports(b); if(ports.size() > 1) return false; } return true; } void counters_worker(ModIndex& index, Module */*module*/, Cell *cell, unsigned int& total_counters) { SigMap& sigmap = index.sigmap; //Core of the counter must be an ALU if (cell->type != "$alu") return; //GreenPak does not support counters larger than 14 bits so immediately skip anything bigger int a_width = cell->getParam("\\A_WIDTH").as_int(); if(a_width > 14) return; //Second input must be a single bit int b_width = cell->getParam("\\B_WIDTH").as_int(); if(b_width != 1) return; //Both inputs must be unsigned, so don't extract anything with a signed input bool a_sign = cell->getParam("\\A_SIGNED").as_bool(); bool b_sign = cell->getParam("\\B_SIGNED").as_bool(); if(a_sign || b_sign) return; //To be a counter, one input of the ALU must be a constant 1 //TODO: can A or B be swapped in synthesized RTL or is B always the 1? const RTLIL::SigSpec b_port = sigmap(cell->getPort("\\B")); if(!b_port.is_fully_const() || (b_port.as_int() != 1) ) return; //BI and CI must be constant 1 as well const RTLIL::SigSpec bi_port = sigmap(cell->getPort("\\BI")); if(!bi_port.is_fully_const() || (bi_port.as_int() != 1) ) return; const RTLIL::SigSpec ci_port = sigmap(cell->getPort("\\CI")); if(!ci_port.is_fully_const() || (ci_port.as_int() != 1) ) return; //CO and X must be unconnected (exactly one connection to each port) if(!is_unconnected(sigmap(cell->getPort("\\CO")), index)) return; if(!is_unconnected(sigmap(cell->getPort("\\X")), index)) return; //Y must have exactly one connection, and it has to be a $mux cell. //We must have a direct bus connection from our Y to their A. const RTLIL::SigSpec aluy = sigmap(cell->getPort("\\Y")); pool y_loads = get_other_cells(aluy, index, cell); if(y_loads.size() != 1) return; Cell* count_mux = *y_loads.begin(); if(count_mux->type != "$mux") return; if(!is_full_bus(aluy, index, cell, "\\Y", count_mux, "\\A")) return; //B connection of the mux is our overflow value const RTLIL::SigSpec overflow = sigmap(count_mux->getPort("\\B")); if(!overflow.is_fully_const()) return; int count_value = overflow.as_int(); //S connection of the mux must come from an inverter (need not be the only load) const RTLIL::SigSpec muxsel = sigmap(count_mux->getPort("\\S")); pool muxsel_conns = get_other_cells(muxsel, index, count_mux); Cell* underflow_inv = NULL; for(auto c : muxsel_conns) { if(c->type != "$logic_not") continue; if(!is_full_bus(muxsel, index, c, "\\Y", count_mux, "\\S", true)) continue; underflow_inv = c; break; } if(underflow_inv == NULL) return; //Y connection of the mux must have exactly one load, the counter's internal register const RTLIL::SigSpec muxy = sigmap(count_mux->getPort("\\Y")); pool muxy_loads = get_other_cells(muxy, index, count_mux); if(muxy_loads.size() != 1) return; Cell* count_reg = *muxy_loads.begin(); if(count_reg->type != "$dff") //TODO: support dffr/dffs? return; if(!is_full_bus(muxy, index, count_mux, "\\Y", count_reg, "\\D")) return; //Register output must have exactly two loads, the inverter and ALU const RTLIL::SigSpec cnout = sigmap(count_reg->getPort("\\Q")); pool cnout_loads = get_other_cells(cnout, index, count_reg); if(cnout_loads.size() != 2) return; if(!is_full_bus(cnout, index, count_reg, "\\Q", underflow_inv, "\\A", true)) return; if(!is_full_bus(cnout, index, count_reg, "\\Q", cell, "\\A", true)) return; //Register output net must have an INIT attribute equal to the count value auto rwire = cnout.as_wire(); if(rwire->attributes.find("\\init") == rwire->attributes.end()) return; int rinit = rwire->attributes["\\init"].as_int(); if(rinit != count_value) return; //Figure out the final cell type based on the counter size string celltype = "\\GP_COUNT8"; if(a_width > 8) celltype = "\\GP_COUNT14"; //Log it total_counters ++; log(" Extracting %d-bit counter to %s hard macro\n", a_width, celltype.c_str()); log(" Decrementer: %s\n", cell->name.c_str()); log(" Output mux: %s\n", count_mux->name.c_str()); log(" Register: %s\n", count_reg->name.c_str()); log(" Comparator: %s\n", underflow_inv->name.c_str()); log(" Count value: %d\n", count_value); /* log("Converting %s cell %s.%s to $adff.\n", log_id(cell->type), log_id(module), log_id(cell)); if (GetSize(setctrl) == 1) { cell->setPort("\\ARST", setctrl); cell->setParam("\\ARST_POLARITY", setpol); } else { cell->setPort("\\ARST", clrctrl); cell->setParam("\\ARST_POLARITY", clrpol); } cell->type = "$adff"; cell->unsetPort("\\SET"); cell->unsetPort("\\CLR"); cell->setParam("\\ARST_VALUE", reset_val); cell->unsetParam("\\SET_POLARITY"); cell->unsetParam("\\CLR_POLARITY"); return; */ } struct CountersPass : public Pass { CountersPass() : Pass("counters", "Extract counter cells") { } virtual void help() { // |---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---|---v---| log("\n"); log(" counters [options] [selection]\n"); log("\n"); log("This pass converts resettable down counters to GreenPak counter cells\n"); log("\n"); } virtual void execute(std::vector args, RTLIL::Design *design) { log_header("Executing COUNTERS pass (mapping counters to GP_COUNTx cells).\n"); size_t argidx; for (argidx = 1; argidx < args.size(); argidx++) { // if (args[argidx] == "-v") { // continue; // } break; } extra_args(args, argidx, design); unsigned int total_counters = 0; for (auto module : design->selected_modules()) { ModIndex index(module); for (auto cell : module->selected_cells()) counters_worker(index, module, cell, total_counters); } if(total_counters) log("Extracted %u counters\n", total_counters); } } CountersPass; PRIVATE_NAMESPACE_END