2025-01-14 14:42:39 +00:00
|
|
|
# SPDX-FileCopyrightText: 2014-2023 Institute for Automation of Complex Power Systems, RWTH Aachen University
|
|
|
|
# SPDX-License-Identifier: Apache-2.0
|
|
|
|
|
2023-06-13 17:48:04 +02:00
|
|
|
nodes = {
|
2025-01-14 14:42:39 +00:00
|
|
|
webrtc_node = {
|
|
|
|
type = "webrtc",
|
|
|
|
|
|
|
|
format = "json"
|
|
|
|
|
|
|
|
# A unique session identifier which must be shared between two nodes
|
|
|
|
session = "my-session-name"
|
|
|
|
|
|
|
|
# Address to the websocket signaling server
|
|
|
|
server = "https://villas.k8s.eonerc.rwth-aachen.de/ws/signaling"
|
|
|
|
|
|
|
|
# Limit the number of times a channel will retransmit data if not successfully delivered
|
|
|
|
# This value may be clamped if it exceeds the maximum value supported
|
|
|
|
max_retransmits = 0
|
|
|
|
|
|
|
|
# Number of seconds to wait for a WebRTC connection before proceeding the start
|
|
|
|
# of VILLASnode. Mainly used for testing
|
|
|
|
wait_seconds = 10 # In seconds
|
|
|
|
|
|
|
|
# Indicates if data is allowed to be delivered out of order
|
|
|
|
# The default value of false, does not make guarantees that data will be delivered in order
|
|
|
|
ordered = false
|
|
|
|
|
|
|
|
# Setting for Interactive Connectivity Establishment
|
|
|
|
ice = {
|
|
|
|
# List of STUN/TURN servers
|
|
|
|
servers = (
|
|
|
|
"stun:stun.0l.de:3478",
|
|
|
|
"turn:villas:villas@turn.0l.de:3478?transport=udp",
|
|
|
|
"turn:villas:villas@turn.0l.de:3478?transport=tcp"
|
|
|
|
)
|
|
|
|
}
|
|
|
|
}
|
2022-03-14 15:32:49 -04:00
|
|
|
}
|