1
0
Fork 0
mirror of https://git.rwth-aachen.de/acs/public/villas/node/ synced 2025-03-09 00:00:00 +01:00

examples: show how to configure signal generator with different settings per signal

This commit is contained in:
Steffen Vogel 2020-08-25 20:28:46 +02:00
parent d0f15403a9
commit 8e883cc66d

View file

@ -2,9 +2,9 @@ nodes = {
signal_node = {
type = "signal",
signal = "sine", # One of "sine", "square", "ramp", "triangle", "random", "mixed", "counter"
values = 4, # Number of values per sample
amplitude = 2.3, # Amplitude of generated signals
signal = [ "sine", "pulse" ], # One of "sine", "square", "ramp", "triangle", "random", "mixed", "counter"
values = 2, # Number of values per sample
amplitude = [ 1.2, 0, 4 ], # Amplitude of generated signals
frequency = 10, # Frequency of generated signals
stddev = 2, # Standard deviation of random signals (normal distributed)
rate = 10.0, # Sample rate